Run
Monitor a live color image and the most recent history.
Default Mode
Detect none glove pixel.
After Trigger
Detect glove pixels and shows history of trigger image list.
Live View Color Image
Image Number represents a frame number of the image from camera.
Inspecting Blue Region is a blue color boundary which represent the area of glove inspection.
Latest Trigger Image History
Latest Trigger Image History is an image list includes 9 images: 4 images before triggered, 4 images after triggered and a triggered image.
Close Button (X) allows you to clear the latest trigger image history.
Red Highlighted Image is an image that triggers glove detection.
History Image
Frame Number represents a frame number of the image from camera.
Glove Pixels shows the number of detected glove pixels.
Lumin Pixel shows the number of detected luminous pixels.
Last updated